LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8VS-06024-F | OMRON S8VS-06024-F Switch Mode Power Supply

S8VS-06024-F | OMRON S8VS-06024-F Switch Mode Power Supply

Brand: OMRON
Name: Switch Mode Power Supply
Model: S8VS-06024-F
Power ratings: 60 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 2.5 A.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)

Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element OMRON S8VS-06024-F.
Burnout Detector compatible with a,
wide-range of heater control methods S8VS-06024-F
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance OMRON S8VS-06024-F.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). R87F-A_A16H-WR waterproof type AC axial flow fan (T40 * _120, wire type).
Rated voltage: 200V.
Allowable voltage range: 85 to 110% of rated voltage OMRON S8VS-06024-F.
Frequency: 50/60Hz.
Rated current: 60Hz--0.098A; 50Hz--0.109A.
Rated input: 50Hz--16W:60Hz--15W.
Rated speed: 50Hz--2690r/min; 60Hz--3040r/min.
Maximum air volume: 60Hz--2.5m3/min; 50Hz--2.3m3/min.
Maximum static pressure: 50Hz--70 S8VS-06024-F OMRON. 9Pa; 60Hz--69.6Pa.
Noise: 50Hz--43dB; 60Hz--46dB.
The axial flow fan with the best cooling is realized.
The design of low noise, high life and good environmental adaptability is considered S8VS-06024-F OMRON.
Bearing with high reliability.
Specification for type 48 and metal blade with resin blade 24.
New waterproof type AC axial fan type R87F-A - AA16H-WR,
(protection structure IP65) S8VS-06024-F.
Through UL, CSA, VDE safety standards, EN/IEC certification of the aircraft is also very rich S8VS-06024-F OMRON. Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.6a .
Caable sheath material: LSZH OMRON S8VS-06024-F.
Cable color: Yellow.
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks.


...More relevant models >>>>