I/O classification: Output.
Internal I/O circuit common: PNP (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
(Long-distance/High-speed Communications Selection).
(W x H x D) mm for 16-point terminals.
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON SRT2-OD08-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
SRT2-OD08-1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs;
PNP (- common); 32 points.
I/O connections: MIL connector OMRON SRT2-OD08-1.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H). Name: Expansion Units e-CON Connector type.
Specifications:Digital inputs and outputs;
4 inputs/ 4 outputs; NPN;
One Expansion Unit can be mounted to one,
CRT1-VAD02@@D or CRT1-VDA02@@D Analog I/O Slave Unit OMRON SRT2-OD08-1.
Standards: --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet SRT2-OD08-1 OMRON.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system SRT2-OD08-1 OMRON.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error SRT2-OD08-1 OMRON. Independent type, the function of the built-in controller is not RS-232C, the maximum 256 points.Specifications: Output, NPN (- common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabiliities SRT2-OD08-1.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required foor input devices such as sensors OMRON SRT2-OD08-1.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.