MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 0.4KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible F1-12MR-UL PDF
F1-12MR-UL
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced F1-12MR-UL PDF.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. Power: 55kw.
Voltage: 200V.
The power factor of the input power factor is up to 0 F1-12MR-UL PDF. 99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus moode F1-12MR-UL Manual.
Equipped with standard power retrogradation function. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points MITSUBISHI INSTRUCTION MANUAL.
Output type: Transistor (source).
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module MITSUBISHI INSTRUCTION MANUAL.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation MITSUBISHI INSTRUCTION MANUAL.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protectionn, using a eight digit password to protect your program F1-12MR-UL INSTRUCTION MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time F1-12MR-UL Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).