Power: 45kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current F1-30MR-UL PDF.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Power: 3.7kw.
Voltage: 200V.
Purpose: high frequency braking resistor
F1-30MR-UL
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter F1-30MR-UL PDF.
Three types of discharge resistors are available.
Please select according to the required braking torque. Input points: 16 points.
Output points: 16 points.
Output form: transistor.
Connected programmable logic controller: FX1NC, FX2NC, FX3UC.
FX2NC expansion module can be directly connected to the FX1NC, FX2NC, PLC FX3UC on the expansion of the input and output F1-30MR-UL PDF.
Do not need to connect the cable aand so on, therefore can carry on the compact expansion F1-30MR-UL Manual. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (sinktype) MITSUBISHI INSTRUCTION MANUAL.
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module MITSUBISHI INSTRUCTION MANUAL.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation MITSUBISHI INSTRUCTION MANUAL.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protectionn, using a eight digit password to protect your program F1-30MR-UL INSTRUCTION MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time F1-30MR-UL Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).