LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI F1-20MR-UL Programming Manual PDF

MITSUBISHI F1-20MR-UL Programming Manual PDF

Brand: MITSUBISHI
Product model: F1-20MR-UL
Name: PLC
Sort: Programming Manual
File language: English
File size: 12.73MB
Input / output type: DC input (drain / source).
Input and output points: 8 points.
DC5V internal consumption current: 75mA.
DC24V internal consumption current: 50mA F1-20MR-UL PDF.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points F1-20MR-UL MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A F1-20MR-UL PDF.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power cconsumption F1-20MR-UL Manual.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON F1-20MR-UL PDF.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation MITSUBISHI Programming Manual.
Can reduce the power consumption in the stop. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 45KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes MITSUBISHI Programming Manual.
For the requirements of relatively high precision, even if the load changes are also required to operrate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) MITSUBISHI Programming Manual F1-20MR-UL Programming Manual.
If the given acceleration time is too short, the output frequency of the inverter is far more than thhe change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall F1-20MR-UL Manual.