Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring L26CPU-CM PDF.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm
L26CPU-CM
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement L26CPU-CM PDF.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period L26CPU-CM PDF.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Input points: 8 points.
Rated input voltage: AC100 ~ 120V.
Common way: 8 point / public end MITSUBISHI Programming Manual.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedbackk signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI Programming Manual MITSUBISHI Programming Manual L26CPU-CM Manual. IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An error ooccurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network L26CPU-CM Programming Manual.
Even if the power of the system is cut off,, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime L26CPU-CM Manual.