Redundant CPU data tracking cable length of 1 meters.
Can only be used for MITSUBISHI Q series PLC redundancy CPU.Relay output: 32.
Rated current and voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end, 8 point 1 Public end Q02UCPU PDF.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AY13.Input: 2 channels.
200/100/10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V
Q02UCPU
Uniform output: Transistor (drain type).
DC12/24V.
0.1A/ point.
0.4A/ common end.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application Q02UCPU PDF.
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge Q02UCPU PDF.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to thhe use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment Q02UCPU Manual. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications MITSUBISHI Programming Guide Book. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency) MITSUBISHI Programming Guide Book.
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders. (QD65PD2)Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station) MITSUBISHI Programming Guide Book.
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network.
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data uppdate is improved Q02UCPU Programming Guide Book.
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish thee network can handle large capacity data Q02UCPU Manual.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station.