Control axis: maximum 32 axes.
Compact size and space saving.
Using the same hardware structure and MELSEC-Q series PLC, to achieve the same product installation area, the size of the industry Q03UDCPU PDF.
Using 12 slot substrate, more space and cost savings.
Can share PLC MELSEC-Q power module, substrate, and I/O module.
The control process can be assigned to each CPU module in the multi CPU system, which is equivalent to the intelligent control system
Q03UDCPU
In PC (Computer Personal) CPU.MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on Q03UDCPU PDF.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device Q03UDCPU PDF.
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device with multiple MODBUS communication from the station equipment MITSUBISHI Programming Guide Book. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)Input and output points: 4096 points.
Input / output data points: 8192 points.
Program capacity: 124k.
Basic command processing speed (LD command) S:0 MITSUBISHI Programming Guide Book. 075.
Multiple CPU (co processor loading).
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of MITSUBISHI Programming Guide Book Q03UDCPU Manual.
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measure of how much the user application can store the number of indicators Q03UDCPU Programming Guide Book.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words Q03UDCPU Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.