Control axis: maximum 32 axes.
Teaching operation function: No.
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
Can be set in advance to stop the location Q12HCPU PDF.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / deceleration time
Q12HCPU
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function."1 axes, SSCNET III type.
Control unit: mm, inch, degree, pulse Q12HCPU PDF.
Location data: 600 data / axis.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m.
Absolute position system for determining the origin position is supported by the return data set operation.
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifiier,
Thus greatly reducing the wiring requirements Q12HCPU PDF Q12HCPU Manual.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc MITSUBISHI Programming Manual. .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug. "MES interface module MITSUBISHI Programming Manual.
Need MX MESInterface software and CF card.
Easily connect production equipment and information system.
Through the excellent database sharing function, greatly reduce the cost of information.
By direct connection, the connection process of the enterprise system database (such as MES) is simplified MITSUBISHI Programming Manual.
Module configuration is simple, without any programming.
The data can be monitored in the module side, when a user defined trigger condition occurs,
Will be read in the form of SQL text and send the specified data to the MES.
The network load can be redduced compared with the previous scheme which is based on the gateway PC to obtain / monitor the data Q12HCPU Programming Manual.
Receive information from the MES, perform pre stored SQL tasks.
In addition, the production instructions from the MES are also receeived,
The production information can be downloaded from the database, and the modification of the formula information can be conveniently carried out Q12HCPU Manual.