1Gbps, master / local station.
IE Field CC-Link network is a kind of field network based on Gigabit Ethernet,
Integrated control of the controller, I/O control, safety control, motion control, can carry out a full range of control.
According to the production line, equipment, equipment layout, the star, linear and ring topology of flexible wiring MITSUBISHI R16SFCPU.
Building a flexible network
Star topology
Star connection is carried out among the modules by using switching hubs
R16SFCPU
When using star topology, you can easily add from the station.
Linear topology
Between the modules to carry out a linear connection.
Distribution cost can be reduced.
Ring topology
Ring connection in between each module.
Part of the anomaly occurs from the station, can be through the ring back function,
Use only normal station to continue data link MITSUBISHI R16SFCPU.
Support IE Field CC-Link network synchronous communication function
According to the synchronization period specified by the master station, the control period of the slave station is synchronized by the IE Field CC-Link network.
According to this, the action time of the station can be synchronized with other slave stations which are connected on the same network MITSUBISHI R16SFCPU. Analog input channel number: 4CH.
Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/W26Re.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection: 18 point screw terminal two.
Temperature tracking function can be monitored in real time.
Using Works3 GX in the temperature function, can be real-time tracking temperature, in the confirmation of the temperature waveform and parameter adjustment.
In addition, the temperature can be saved as a CSV file after the export, the use of a variety of purposes.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
Temperatture rising function between modules
By cooperating with the time of arrival of a number of loops, the average temperature is controlled R16SFCPU.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomeenon of thermal expansion R16SFCPU. Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy.