LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4SL-N2GFG-D4N INSTRUCTION sheet PDF

OMRON D4SL-N2GFG-D4N INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4SL-N2GFG-D4N
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.57MB
Actuator: Roller plunger (Metal roller).
Cable length: 3 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 2NC/2NO (slow-action).
Smallest Class of Safety Limit Switches the World D4SL-N2GFG-D4N PDF.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available D4SL-N2GFG-D4N
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller lever (resin lever, resin roller) D4SL-N2GFG-D4N PDF.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4SL-N2GFG-D4N PDF. )
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON IINSTRUCTION sheet D4SL-N2GFG-D4N Manual.
Certified standards: UL, EN (TÜV), and CCC. Ratings: 3 A.
Actuator: Hinge lever.
Terminals: Solder terminals.
Contact form: SPDT.
Sealed Subminiature Basic.
Switch Conforming to IP67.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing,
making this switch ideal for places subject to,
water spray or excessive dust OMRON INSTRUCTION sheet.
Ideal for automobiles, automatic vending,
machines, refrigerators, ice-making equipment,
bath equipment, hot-water supply systems, air,
conditioners, and industrial equipments, which,
require high environmental resistance OMRON INSTRUCTION sheet.
Models available with UL, CSA, and VDE safety,
standard compliance. Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: Pg13.5.
2NC (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened D4SL-N2GFG-D4N INSTRUCTION sheet. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operationn prevented by special Operation Key D4SL-N2GFG-D4N Manual.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1).