Type: Standard.
Contact gap: 3 mm min.
Mounting: Screw mounting.
Contact form: SPST-NO+SPST-NC.
Door Interlock Power.
Switch with Minimum.
Contact gap of 3 mm D4SL-N4AFG PDF.
Offers the minimum contact gap of 3 mm required.
for power switches as standard equipment.
Safety considerations include a double return spring,
and direct drive positive contact opening feature.
Pull-on lock model for easy maintenance is also available
D4SL-N4AFG Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ D4SL-N4AFG PDF.
Conduit size (See Note.): GG1/2 D4SL-N4AFG Manual.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
D4SL-N4AFG PDF.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point OMRON INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames OMRON INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contacct forms in addition to the previous contact forms 1NC/1NO and 2NC OMRON INSTRUCTION sheet D4SL-N4AFG INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4SL-N4AFG Manual.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.