File size: 12.21MB
Output points: 64 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two LD75P2-CM PDF.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called LD75P2-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol LD75P2-CM PDF. Cable length: 1.0m.
Weight: 0.23kg.
Definition 1: conductor by one or a plurality of mutually insulated and insulating protective layer made of,
A conductor of electricity or information from one place to another.
Definition 2: usually by a few or several groups (each with at least two wires) cable rope twisted the similar,
Each group of wires are insulated from each other, and are often twisted around a center,
The entire outer bread has a highly insulated cover LD75P2-CM PDF.
The cable has the characteristics of internal power and external insulation. Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract)), and reduce the operation cost LD75P2-CM datasheet.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniiform, to ensure that the control object no local burning or thermal expansion LD75P2-CM datasheet.
No idle running, with energy saving effect, can reduce operating costs.
Related products
MITSUBISHI
Positioning module
LD75D1-CM
MITSUBISHI Positioning module LD75D1-CM
Differential output. Axis of control: 1. Maxi
MITSUBISHI
Contact output module
LY10R2-CM
MITSUBISHI Contact output module LY10R2-CM
Output points: 16 points. Rated output voltag
MITSUBISHI
Positioning module
LD75D4-CM
MITSUBISHI Positioning module LD75D4-CM
Differential output. Axis of control: 4. Maxi
MITSUBISHI
IE CC-Link field network host module
LJ72GF15-T2-CM
MITSUBISHI IE CC-Link field network host module LJ72GF15-T2-CM
IE Field CC-Link intelligent equipment statio