IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime.
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be used as a screw relay terminal.Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence) MITSUBISHI LJ72GF15-T2-CM.
Input / output occupied points: 16 points (I/O distribution: output 16 points)
LJ72GF15-T2-CM
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged MITSUBISHI LJ72GF15-T2-CM.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible MITSUBISHI LJ72GF15-T2-CM.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability LJ72GF15-T2-CM MITSUBISHI. Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch LJ72GF15-T2-CM MITSUBISHI.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm LJ72GF15-T2-CM MITSUBISHI.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analogg output LJ72GF15-T2-CM.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period MITSUBISHI LJ72GF15-T2-CM.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.