MITSUBISHI LX42C4-CM datasheet PDF

Brand: MITSUBISHI
Product model: LX42C4-CM
Name: DC input module
Sort: PDF datasheet
File language: English
File size: 12.21MB
"IE Field CC-Link master / local station
Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations LX42C4-CM PDF LX42C4-CM
Also, when you need to change the system, you only need to change the parameters.
High degree of freedom network
Build star, linear, star and linear mixed model, and ring network,
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple LX42C4-CM PDF. "RS-232.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication LX42C4-CM PDF.
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate connection.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply create a corresponding protocol for communication.
The content of the communication protocol that can be created in the list,
Can also be simply edited. Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protecttion function, with 3000V photoelectric isolation LX42C4-CM datasheet.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible LX42C4-CM datasheet.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.
Related products
MITSUBISHI
RS-422/485 adapter
L6ADP-R4-CM
MITSUBISHI RS-422/485 adapter L6ADP-R4-CM
Maximum transmission speed: 115.2kps. DC5V i
MITSUBISHI
DC input module
LX41C4-CM
MITSUBISHI DC input module LX41C4-CM
Input points: 32 points. Rated input voltage:
MITSUBISHI
Analog output module
L60DA4-CM
MITSUBISHI Analog output module L60DA4-CM
Output channel numer: 4ch. Output voltage: D
MITSUBISHI
Analog input module
L60AD4-CM
MITSUBISHI Analog input module L60AD4-CM
Numer of input channels: 4ch. Input voltage: