Input points: 32 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: 32 points).
External wiring connection mode: 40 pin connector.
The input and output module is also called control module, which can output signal when there is control requirement,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on.
Cable length: 1.0m.
Weight: 0.23kg.
Definition 1: conductor by one or a plurality of mutually insulated and insulating protective layer made of,
A conductor of electricity or information from one place to another.
Definition 2: usually by a few or several groups (each with at least two wires) cable rope twisted the similar,
Each group of wires are insulated from each other, and are often twisted around a center,
The entire outer bread has a highly insulated cover MITSUBISHI LX41C4-CM
LX41C4-CM
The cable has the characteristics of internal power and external insulation. Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact) MITSUBISHI LX41C4-CM.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI LX41C4-CM.
Communication protocol is a standard Modbus protocol or custom protocol LX41C4-CM MITSUBISHI. The connector is converted to a screw relay terminal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output LX41C4-CM MITSUBISHI. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output LX41C4-CM MITSUBISHI. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.DC5V internal consumption current: 0.08A.
Weight: 0.13kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcompputer,
Function is the interface of the programmable logic controller and the field control LX41C4-CM.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
Thhe programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module MITSUBISHI LX41C4-CM.