Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-HTA-CPAC21 AC/DC24 PDF
K3HB-HTA-CPAC21 AC/DC24
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
6 measurement methods,The protection of the decentralized power supply to the power system,
The relay is smaller, and the protection unit is more enriched K3HB-HTA-CPAC21 AC/DC24 PDF.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system K3HB-HTA-CPAC21 AC/DC24 PDF.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring.
Control supply voltage: 200 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element evven if one heater el,
ement among several heater elements has been burned out K3HB-HTA-CPAC21 AC/DC24 datasheet.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-HTA-CPAC21 AC/DC24 datasheet.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.