Safety outputs *1: Instantaneous, 2; OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *2: 2(Semiconductor).
No. of input channels: 1 or 2 channels GX-ID1618 PDF.
Max. OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units)
GX-ID1618
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set GX-ID1618 PDF.
-Two logical AND connection inputs. Terminals: Push-In Plus terminal blocks.
Type: Input *1.
Points: 16.
Internal I/O circuit common: NPN (– common).
Rated voltage: 24 VDC.
I/O Relay Terminals with 16 Points and,
Push-In Plus terminal blocks to,
Downsize Control Panels and Save Labor GX-ID1618 PDF.
I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays.
Push-In Plus terminal blocks are used to save wiring work in,
comparison with traditional screw terminals. (Wiring time is,
reduced by 60%* in comparison with traditional screw terminals OMRON INSTRUCTION MANUAL. ).
Work is reduced ever further with one-step cable connection to the PLC.
Diode provided for coill surge absorption GX-ID1618 Manual.
Operation indicators for immediate recognition of I/O signal status.
Accepts G3RV Slim I/O SSRs.
DIN Track or screw mounting OMRON INSTRUCTION MANUAL. Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: No.
Applicable output load: 150 A, 180 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC OMRON INSTRUCTION MANUAL.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The SSmart FB Library for the G3ZA,
can also be used GX-ID1618 INSTRUCTION MANUAL.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection GX-ID1618 Manual.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.