Input capacity: 16 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min.
OFF voltage: 5 VDC max.
OFF current: 1.0 mA max.
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
I/O power supply current con sumption: 5 mA max.
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
communications.
the maintenance.
The expansion unit can be connected.
depending on the system.
high-speed processing.
setting with rotary switch and with tool software.
possible for maintenance.
Name: Expansion Units.
Specifications: inputs ;
8 inputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON GX-ID1621.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system
GX-ID1621
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON GX-ID1621. Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 inputs PNP.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON GX-ID1621.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O, NPN (input: + common, output: - common), 8 inputs/8 outputs.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Coommon Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance GX-ID1621.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one cconnector for two outputs are available to make easier,
connection with hydraulic valve devices GX-ID1621.
(Models with 16 outputs and models with 16 mixed I/O)