LK166
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-XAA-CPAC21 Communications Manual PDF

OMRON K3HB-XAA-CPAC21 Communications Manual PDF

Brand: OMRON
Product model: K3HB-XAA-CPAC21
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.83MB
Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment K3HB-XAA-CPAC21 PDF.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load) K3HB-XAA-CPAC21
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator K3HB-XAA-CPAC21 PDF.
Inputs are isolated from the power supply. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages and undervoltages for three-phase 3-wire,
or 4-wire power supplies K3HB-XAA-CPAC21 PDF.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and undervoltages.
World-wide power specifications supported by one UUnit,
(switchable using DIP switch) OMRON Communications Manual K3HB-XAA-CPAC21 Manual.
Relay status can be monitored using LED indicator. Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents OMRON Communications Manual.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load) OMRON Communications Manual.
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages, undervoltages, phase sequence, and,
phase loss for thrree-phase 3-wire or 4-wire power supplies with,
just one Unit K3HB-XAA-CPAC21 Communications Manual.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power,
supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Output overvoltages and undervoltaages using separate relays K3HB-XAA-CPAC21 Manual.
World-wide power specifications supported by one Unit,
(switchable).
Output status can be monitored using LED indicator.
Related products
OMRON
Voltage and current panel meter
K3HB-XAD-L2AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAD-L2AT11 AC/DC24
Input type: DC current input. Output type: l
OMRON
Time interval table
K3HB-PNB-CPAC21 AC/DC24V
OMRON Time interval table K3HB-PNB-CPAC21 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Rotating pulse meter
K3HB-RPB-CPAC21 AC100-240
OMRON Rotating pulse meter K3HB-RPB-CPAC21 AC100-240
Input type: PNP input type. Event input term