Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) K3HB-XVA-DRT1 PDF.
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods
K3HB-XVA-DRT1
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-XVA-DRT1 PDF.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2 K3HB-XVA-DRT1 PDF.
CE marking and cUL certified (K8AC-H2@@@). Type: Temperature input.
Output relays: 1 relay.
Input types: TThermocouple K3HB-XVA-DRT1 Manual.
Setting units (setting range): Setting unit: 10°C/°F*.
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored OMRON Communications Manual.
Temperature monitoring in slim design with a width of just 22.5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation OMRON Communications Manual.
Alarm status identification with LED indicator.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A OMRON Communications Manual.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burnned element even if one heater el,
ement among several heater elements has been burned out K3HB-XVA-DRT1 Communications Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-XVA-DRT1 Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.