LK166
Home >> Supply >> FR-F842-09620-2-60 MITSUBISHI FR-F842-09620-2-60 Rectifying partial off type frequency converter
Search
Information sort

FR-F842-09620-2-60 MITSUBISHI FR-F842-09620-2-60 Rectifying partial off type frequency converter


Input and output points: 32 points.
Input points: 16 points.
Input specifications: drain / source.
Output points: 16 points.
Output form: transistor output (source).
Power consumption: 8W.
Weight: 0.2KG.
Outline dimension: 34x90x87mm.
Hard and compact type third generation micro programmable controller FR-F842-09620-2-60.
Connector type input and output type provincial connection.
Greatly strengthened the industry''s highest level of high-speed processing and positioning and other built-in features FR-F842-09620-2-60.
High cost of the province space models.
FX3UC in the province of space, the province also greatly strengthened the connection of high-speed processing and positioning and other built-in features.
The host is built in DC24V power supply, the connector input and output form of the transistor output FR-F842-09620-2-60.
In addition, according to the product mix can also achieve network communications, analog control, data collection and other functions.
Third generation high function micro programmable controller.
Connector type can save space, province wiring MITSUBISHI FR-F842-09620-2-60.
Built in high speed processing and positioning.
Ultra small size, control points to 256 points.
Construction of CC-Link remote I/O 384 points. The connector is converted to a screw relay terminal.
MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V MITSUBISHI FR-F842-09620-2-60.
Power: 450kw.
SLD converter rated current: 962A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON MITSUBISHI FR-F842-09620-2-60.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop. Analog input expansion board (2 channel).Input points: 8 points.
Output points: 6 points.
Power supply voltage: AC100-240V.
Output type: relay output.
Built in CPU, power supply, input and output. While maintaining the convenience of FX1N while improving performance.
Special adaptor and function expansion board can be installed and used FX3 series.
High speed operation FR-F842-09620-2-60.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.

Related supply information