Analog input channel number: 8CH.
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: plus or minus 15V.
External wiring connection mode: 18 point screw terminal.
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Analog input current: -.
Digital output value: -.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Works3 GX can be used to easily set the critical value of the input and output signals.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs.
Channel insulation can ensure the accurate signal transceiver.
Isolation amplifiers are not required to prevent inter channel current and interference current.
The input and output module installation number: 8.
Can install module: MELSEC-Q series module.
DIN guide rail mounting adapter type: Q6DIN1.
Size (H) * (44.1mm) * (W) * (D): * 328mm * 98mm.
Substrate module for mounting various modules of MELSEC-Q series.
Extended use of Q series expansion substrates in the following extensions MITSUBISHI R60ADV8. "Analog input channel number: 4CH.
Available thermocouple: -
R60ADV8
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range MITSUBISHI R60ADV8.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: none.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater MITSUBISHI R60ADV8.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control R60ADV8 MITSUBISHI. Can be combined with the function of the following two points.
Heating function between modules R60ADV8 MITSUBISHI.
Peak current suppression function between modules.
Temperature rising function between modules
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion R60ADV8 MITSUBISHI. Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy. Analog input channel number: 4CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Channel insulation.
Similar to the input and output modules, analog quantity module is the interface between the sensor and the programmable controlller R60ADV8.
The difference between the input and output modules is that it is dealing with analog voltage and current signals rather than ON/OFF signals.
The analog module MELSEC iQ-R series is equipped with high-speed conversion (80 s/CCH), high resolution (1/32000), channel insulation, abnormal signal detection and other convenient features,