CC-Link/LT master station.
Transmission speed: 2.5Mbps.
Remote input / output: 1024 points.
16 point mode.
In the cabinet, the device can also respond to high speed.
Excellent response performance is achieved.
Can be selected according to the transmission distance 2.5Mbps, 625kbps, 156kbps.
Comfortable environment without network awareness.
Parameter settings that do not require any trouble.
Moreover, the transmission speed only through the master module to set, can easily use the remote I/O.
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.The connector is converted to a screw relay terminal.Can be used as a screw relay terminal. Positive common end use.Can be used as a screw relay terminal.Convert connectors to e-CON.Can be used as a screw relay terminal MITSUBISHI LJ61CL12. Convert connectors to e-CON.AnyWireASLINK master station
LJ61CL12
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points MITSUBISHI LJ61CL12.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module MITSUBISHI LJ61CL12.
In addition to the 2 wire type, the local power supply can be connected with the 4 wire type mixed use.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power supply LJ61CL12 MITSUBISHI.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load LJ61CL12 MITSUBISHI. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Number of input channels: 8ch.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50 LJ61CL12 MITSUBISHI.
Conversion speed: 40ms/ch.
Resolution: 0.1.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analog output LJ61CL12.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period MITSUBISHI LJ61CL12.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.