Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations.
Also, when you need to change the system, you only need to change the parameters.
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple. "
Control axis: maximum 4 axes.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 4 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control MITSUBISHI LJ71GF11-T2-CM.
Equipped with standard synchronous encoder and color detection function necessary function
LJ71GF11-T2-CM
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program.
Let motion control more simple. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module MITSUBISHI LJ71GF11-T2-CM. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring MITSUBISHI LJ71GF11-T2-CM.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm LJ71GF11-T2-CM MITSUBISHI.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement LJ71GF11-T2-CM MITSUBISHI.
High speed, smooth continuous analog output.
Waveform output fuunction
Equipped with the industry''s first waveform output function LJ71GF11-T2-CM MITSUBISHI LJ71GF11-T2-CM.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period MITSUBISHI LJ71GF11-T2-CM.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.