Name: Slice I/O Units; Digital I/O Units.
Specifications: 8 outputs NPN.
Standards: CE, UC1, L.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Classification: Analog Output Terminal.
I/O points: 1 or 2 (selectable with DIP switch).
Compact Analog Output Model is the,
Same Shape as 16-point Remote I/O Terminals.
Two output points or 1 output point is selectable.
Resolution: 1/6,000.
105 x 48 x 50 (W x H x D). Short/disconnection detection: Supported GRT1-OD8-1 OMRON.
Specifications: Inputs, PNP (- common), 32 points.
I/O connections: Clamp terminals
GRT1-OD8-1
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance GRT1-OD8-1 OMRON.
Single-step wiring by simply inserting pole terminals. Input type: Platinum-resistance thermometer input.
I/O points: 4 inputs allocated 4 input words at the Master Unit,
(8 input words allocated when 1/100 display mode is selected).
Temperature Input Terminal with Smart Functionality.
The Temperature Input Terminal can be used with almost the same functionality as a.
Analog Input Terminal, such as with scaling and comparator functions GRT1-OD8-1 OMRON.
Enhanced performance is provided with functionality specific to the Temperature,
Input Terminal, such as the recording the operating time in a preset temperature,
range and temperature difference detection between input channels.
Classification: Analog input.
I/O points: 4 inputs (Resolution: 30, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler funcction GRT1-OD8-1.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function.
Two I/O points can be allocated to any two of the followingg values: analog,
input, peak/bottom, top, valley, or rate-of-change GRT1-OD8-1. Values without an,
allocated I/O point can be read with message communications.