LK166
Home >> Products >> OMRON >> Master slave station products >> EtherCAT remote I/O terminal >> GX-OD1628 OMRON GX-OD1628

GX-OD1628 OMRON GX-OD1628

Brand: OMRON
Name: Digital I/O Terminal 3-tier Terminal Block Type
Model: GX-OD1628
Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.

Name: Repeater Unit.
Specifications: A sub-trunk line can be,
connected downstream,
(for trunk-branch line configuration),
or further branching is enabled downstream,
(for configurations with no wiring restrictions),
in the same way as for a Master Unit.
A Repeater Unit can be used to branch,
the trunk line and increase the,
number of connected Units,
as well as to extend the length of the,
communications line OMRON GX-OD1628 GX-OD1628
Standards: CE, U, U1, L, N.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection OMRON GX-OD1628.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application. Name: Clamp Terminal Blocks.
Specifications: Outputs; 16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON GX-OD1628.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Outputs;
NPN (- common);
16 ppoints GX-OD1628.
I/O connections: MIL connector(Connector with 10-cm cable).
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Termminals GX-OD1628.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).


...More relevant models >>>>