Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.
Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Convert connectors to e-CON.Converts the built-in I/O function to the screw terminal.Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module MITSUBISHI FA-TH16YRAC20S. Output points: 16 points.
Rated output voltage: DC24V/AC240V
FA-TH16YRAC20S
Rated open and close current: 2A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called MITSUBISHI FA-TH16YRAC20S.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. AnyWireASLINK master station.
Transmission distance: the longest 200m MITSUBISHI FA-TH16YRAC20S.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points FA-TH16YRAC20S MITSUBISHI.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor FA-TH16YRAC20S MITSUBISHI.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition FA-TH16YRAC20S MITSUBISHI.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, the local power suupply can be connected with the 4 wire type mixed use FA-TH16YRAC20S.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply MITSUBISHI FA-TH16YRAC20S.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.