Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TH16YRA11S Terminal module MITSUBISHI FA-TH16YRA11S

FA-TH16YRA11S Terminal module MITSUBISHI FA-TH16YRA11S

Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YRA11S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Positive common end use. Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function MITSUBISHI FA-TH16YRA11S.
Latch counter function.
Sampling counter function.
Periodic pulse counter function FA-TH16YRA11S
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time MITSUBISHI FA-TH16YRA11S.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized MITSUBISHI FA-TH16YRA11S.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized. Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA FA-TH16YRA11S MITSUBISHI.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm FA-TH16YRA11S MITSUBISHI.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement FA-TH16YRA11S MITSUBISHI.
High speed, smooth continuous analoog output FA-TH16YRA11S.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period MITSUBISHI FA-TH16YRA11S.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.


...More relevant models >>>>