Power: 1.5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor .
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table
FR-HEL-H3.7K
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate FR-HEL-H3.7K.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor .
The installation of thermal relay, to avoid overheating and burn the braking resistor. Cable length: 30 meters.
For QnA/A/FX (FX1, FX2, FX2C) CPU and GOT connection between.
For connection between FA-CNV_CBL and GOT.
For connection between FX-2PIF and GOT.
For connection between FX-422AW0 and GOT FR-HEL-H3.7K.
For serial communication module AJ71QC24 (N) -R4 and GOT connection between .
For connection between AJ65BT-G4-S3 and GOT. Max input / output points: 20 points.
Power supply voltage: DC24V.
Input points: 12 points.
Output points: 8 points.
Output type: relay.
Power consumption (W): 20.
Weight (kg):0.4.
Size (WxHxD) mm:75x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city poower, built-in 8K step EEEPROM memory, no battery, easy to maintain FR-HEL-H3.7K.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BBD board to extend a small amount of I/O FR-HEL-H3.7K.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
FR-HEL-H3.7K Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FR-HEL-H3.7K&select=5