Input voltage range: AC100 ~ 120V/AC200 ~ 240V.
Output voltage: DC5V.
Output current: 8A.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference
FR-HEL-H30K Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC. Motor series: medium inertia, medium power.
Rated output power: 3.5kw FR-HEL-H30K.
Rated speed: 2000r/min.
Whether to bring the brakes: with .
Shaft end: Standard (straight).
Power supply: 400V type.
Protection level: IP65 (IP67).
Features: medium inertia from low speed to high speed three modes for selection, suitable for different applications.
Application examples: transmission machinery, robots, X-Y working platform.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed FR-HEL-H30K.
All motor dimensions are the same as before and all are compatible with the wiring. Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: 30mA.
External wiring connection mode: 18 point screw terminal.
Voltage input
Analog input voltage: -.
Digital output value: -.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Reduce downtime and reduce maintenance costs through anomally detection
Works3 GX caan be used to easily set the critical value of the input and output signals FR-HEL-H30K.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs.
Channel insulation can ensure the accurate signal transceiver.
Model withh "" -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current FR-HEL-H30K.
FR-HEL-H30K Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FR-HEL-H30K&select=5