OMRON GX-OD3228 Safety Precautions PDF

Brand: OMRON
Product model: GX-OD3228
Name: EtherCAT Remote I/O Slaves
Sort: Safety Precautions
File language: English
File size: 0.37MB
Input capacity: 16 points.
Rated current (ON current):
0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal) GX-OD3228 PDF.
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation GX-OD3228
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max GX-OD3228 PDF.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications GX-OD3228 PDF.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.

(One expansion unit per one I/O terminal unit GX-OD3228 Manual. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing OMRON Safety Precautions.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance. Name: CompoNet Gateway Unit for CC-Link.
Specifications: CC-Link Communications,
Specification, Station Type,
Remote device stations;
Number of stations occupied: 4 OMRON Safety Precautions.
CC-Link Version: Version 1.10 or 2.00.
(Selected using mode switch.);
CompoNet Communications Specification,
communications Types of,
Remote I/O Communications;
Maximum I/O capacit, Word Slave Units:
2,048 I/O points total(1,024 inputs and,
1,024 outputs)Bit Slave Units:
512 I/O points total OMRON Safety Precautions.
(256 inputs and 256 outputs)
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material costt can be reduced GX-OD3228 Safety Precautions.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee GX-OD3228 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
Related products
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-OD3218
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-OD3218
Input capacity: 32 points. Rated current ON
OMRON
EtherCAT Remote I/O Terminals
GX-OD1611
OMRON EtherCAT Remote I/O Terminals GX-OD1611
Input capacity: 16 points. Rated current ON
OMRON
EtherCAT Remote I/O Terminals
GX-OC1601
OMRON EtherCAT Remote I/O Terminals GX-OC1601
Input capacity: 16 points. Mounted relays: N
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-OD1622
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-OD1622
Input capacity: 16 points. Rated current ON